STATUTORY INSPECTION SERVICES UNDER THE FACTORIES ACT, 1948 AND GUJARAT FACTORY RULE, 1963 (GFR)


Form 9, Inspection and Certification of lift/ hoist under Section 28/ Rule 58
Form 10, Inspection and Certification of lifting machine, lifting tools and tackles under Section 29/ Rule 60
Form 11, Inspection and Certification of Pressure Vessels and Plant under Section 31/ Rule 61 with Hydro test
Section 41, Inspection and certification of Thermic Fluid Heater, Oven and Dryers
Section 21, Inspection and certification of Dangerous machines
Form 1A, Inspection and Certification of Structural stability by computer analysis and load
Section 6 & Section 112, Calculation, visual inspection of corrosion
Form 26A, Inspection and certification of Dust & Fume Ventilation system under Section 87
Section 111A, In-house as well as at-site training
Drawing approval as per GFR
TESTING SERVICES (INSPECTION AND CERTIFICATION) AS PER GOVT. REQUIREMENT OR ON AD-HOC BASIS


Lifting Tools and Pressure Vessel Testing
Crane and Hook Testing
Hydrastatic Testing
Load Testing
Air Receiver Monitoring
Pipeline Testing
Non Destructive Testing (NDT)
Welding Testing
Pullout Testing
Material Testing
Instrument Calibiration
AUDITING SERVICES


Energy Audit
Fire and Safety Audit
Electrical Safety Audit
Training for Safety (including Statutory Training with Certificate)
C.E. Certificate for Fitness Certification, EPCG, Import-Export
Approved Valuer- Valuation of Plant Building and Machinery
Structure Stability/ Load Calculation (Rack/ Civil structure)
On-site/ Off-site Emergency Plan
Quality Risk Assessment


Risk Assessment Study, HAZOP Study
HIRA (Hazard Identification and Risk Analysis)
Noise and Lux Measurement
Earth Pit Calibration
Flow Measurement of Pipeline
Dry/ Wet Tank Calibration
Corrosion Mapping
QA/ QC and Inspection
Advance NDT (Eddy Current Testing, Magnetic Flux Leakage, Phased Array Ultrasonic Testing, etc.)
ENERGY MANAGEMENT SERVICES - AS PER GUJARAT ENERGY DEVELOPMENT AUTHORITY (GEDA) AND BUREAU OF ENERGY EFFICIENCY (BEE)


Consult the Designated Customers (DCs) on reducing their Specific Energy Consumption (SEC)
Track the reduction of Specific Energy Consumption (SEC) through KPIs such as Energy Consumption, Efficiency gains, Utility Costs and Cost of Production
Root Cause Analysis (RCA) and Expected Reading vs Actual Value analysis for the above mentioned KPIs
Issue Energy Saving Certificate (ESCerts) as per Bureau of Energy Efficiency (BEE) to Designated Customers (DCs) after successful implementation of PAT cycle
CALIBRATION AND CERTIFICATION, AS PER WEIGHT AND MEASUREMENT ACT, 1976


Calibration of existing and new Weighing Machines and Systems
Completion of Government Certification, Re-verification, and Stamping
Supply of Dead Weights for testing on a Hiring basis
Pressure Gauge Calibration (up to 600 kg/cm2), under Gujarat Factories Act Section 31, Rule 61, Sr. No. 11(A) of Form 11
Get in touch
Reach out for Inspection, Testing and Audit services or Expert Energy advice
Phone
+91-9376854704
aruconsultancy11@gmail.com